Home 5 Project 5 Subsurface Remediation with AS/SVE Systems – Piedmont

Subsurface Remediation with AS/SVE Systems – Piedmont

Project Goals and Outcomes

Client: Chemical company undergoing environmental redevelopment
Location: Historic Industrial Plant, Piedmont
Client’s Goal: Remediate unsaturated soils and groundwater contaminated with VOCs, achieving risk threshold concentrations (CSCs).
Our Role: Design and supply of integrated Air Sparging (AS) and Soil Vapor Extraction (SVE) systems.
Result: Progressive reduction of contaminant mass, plume control, and full compliance with emission limits.

Performance of the Plant

30 wells

Total AS/SVE Installed

16 connected to plant area “A” and 14 to plant area “B”

5,850Nm3/h

Total Extracted Air Flow (SVE)

2,160Nm3/h

Total Insufflated Air Flow Rate (AS)

The GEOSTREAM Solution

Integrated system with two AS units combined with two SVE units, operating in separate areas of the plant.

  • Air Sparging (AS): injection of compressed air into the subsurface to mobilize contaminants.
  • Soil Vapor Extraction (SVE): extraction of contaminant vapors from soil pores with subsequent treatment with activated carbon.
    Installed packages ensure modularity, small footprint and construction uniformity between the two areas of operation.